lgOlulimi
Ekirungo ekifuumuula amazzi ekitali kitereevu .

Ekirungo ekifuumuula amazzi ekitali kitereevu .

Erinnya ly'ekintu: Condenser etali butereevu efuumuuka .
Enkola y’okutambuza ebbugumu: Wakati w’ekisenge ky’okukyusa ebbugumu erirabika .
Ebipimo okutwaliza awamu: empisa-Made .
Omutendera gw'obukuumi: IP55 level, enfuufu n'amazzi agafuuwa
Obugumu bw'ekisenge ky'ebbugumu: nga 0.8mm .
Embeera y'amasannyalaze: nga 380V 50Hz
Oba okugerageranya: ebipipa ebiwanyisiganya ebbugumu tebipimibwa .
Anti-Ebipimo by’okutonnya: tebikozesebwa mu kiseera ky’obutiti ku kufulumya amazzi munda mu payipu .
Okufuga omuwendo gw’amazzi agakulukuta: Omuwendo gw’amazzi agakulukuta gwetaaga okuba mu bitundu 80% eby’omuwendo gwa dizayini, okwewala omuwendo gw’amazzi amatono agava ku kutonnya kw’ekitundu .
Ekika ky'ebintu: LZBF
Weereza okwebuuza .

Ennyonnyola y'ebintu .

 

Indirect evaporative condenser okusinga erimu ekikyusa ebbugumu, enkola y’okutambula kw’amazzi n’enkola y’okutambula kw’abawagizi. Indirect evaporative condenser yeesigamiziddwa ku kufuumuuka okufuumuuka n’okuwanyisiganya ebbugumu mu ngeri ey’amagezi, enkola y’okugabanya amazzi ey’okungulu etali butereevu efuumuuka. Continuously downward spray cooling water, in indirect evaporative condenser heat exchanger tube surface to form a water film, the heat exchanger tube and the tube heat fluid occurs sensible heat exchange and heat transfer to the cooling water outside the tube, at the same time indirect evaporative condenser heat exchanger tube outside the cooling water and the air is mixed, the cooling water to the air to give off the evaporative Latent heat of evaporation of the cooling water to the Empewo n’okunyogoza, olwo ebbugumu ly’amazzi agafuumuuka okumpi n’ebbugumu lya bbaatule ennyogovu ery’empewo.

 

Closed-Circuit Cooling Tower Manufacturing Facility

 

Olw’enkulaakulana ya ssaayansi ne tekinologiya egenda mu maaso, tekinologiya ow’okunyogoza okufuumuuka (evaporative cooling technology) owa indirect evaporative condenser alongooseddwa nnyo, era enkola zaayo ez’okukozesa zeeyongera. Okugeza, mu mulimu gw’eddagala, tekinologiya wa kondensa ow’okufuumuuka atali butereevu asobola okukozesebwa okunyogoza riyaaktori n’eby’okwawula okulongoosa obulongoofu n’amakungula g’eddagala; Mu mulimu gw’okufumbisa emmere, tekinologiya wa kondensa ow’okufuumuuka atali butereevu asobola okukozesebwa mu kutereka ennyogovu ne loole eziteekebwa mu firiigi okukuuma obulungi n’omutindo gw’emmere. Ekifaananyi ekikwata ku nsonga eno mu bujjuvu.

 

Customer Site Installation of Closed-Circuit Cooling Tower

 

Mu kumaliriza, indirect evaporative condenser kika kya bulungibwansi, okukekkereza amaanyi, okukuuma obutonde bw’ensi n’obukuumi mu firiigi. Indirect evaporative condenser applications zigenda zeeyongera okugaziwa, era ejja kukola kinene nnyo mu mulimu gwa firiigi mu biseera eby’omu maaso.

 

Hot Tags .: Indirect Evaporative Condenser, China Indirect Evaporative Condenser Abakola, Abagaba, Ekkolero

Weereza okwebuuza .